Atomic Absorption Spectrophotometers
Labnics
LAAS-A Series

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The           S-H background correction capability at 1.8A better than 30 times.
  • Lamp Turret– 6


  • Learn more about Atomic Absorption Spectrophotometers-LAAS 110A......

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A better than 30 times.
  • Lamp Turret–6


  • Learn more about Atomic Absorption Spectrophotometers-LAAS 120A....

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
  • Lamp Turret–4


  • Learn more about Atomic Absorption Spectrophotometers-LAAS 130A....

    LAAS-B Series

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame; 5cm single slot all titanium burner for     oxygen rich flame.


  • Learn more about Atomic Absorption Spectrophotometre-LAAS-110B.....

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.


  • Learn more about Atomic Absorption Spectrophotometre-LAAS-120B.....

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–4.
  • Lamp Current Adjustment–Automatic adjustment and display.Wide pulse current: 0~25mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.


  • Learn more about Atomic Absorption Spectrophotometre-LAAS-130B.....

    LAAS-210  

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret– 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity)

    Learn more about Atomic Absorption Spectrophotometre-LAAS-210.....

  • LAAS-320

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Number– 2 lamps (one preheating).
  • Burner– 10cm single slot all titanium burner.


  • Learn more about Atomic Absorption Spectrophotometre-LAAS-320.....

    LAAS-810  

  • Wavelength Range– 190-900nm.
  • Zeeman background correction technology
  • Lamp Turret– Automatic 8 x 2 lamp turret (Two high performance hollow cathode lamps can be mounted on       each turret)
  • Flame mode- 0.2, 0.4, 0.8, 1.6mm
  • Graphite furnace mode- 0.2, 0.4, 1.2mm



  • Learn more about Atomic Absorption Spectrophotometre-LAAS-810.....

    LAAS-990

  • Wavelength Range– 190-900nm
  • Background Correction– Deuterium lamp 1.0 Abs
  • Burner– Titanium alloy burner


  • Learn more about Atomic Absorption Spectrophotometre-LAAS-990......
     

     

     