Atomic Absorption Spectrophotometers– LAAS Series

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The        S-H background correction capability at 1.8A better than 30 times.
  • Lamp Turret– 6

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The       S-H background correction capability at 1.8A better than 30 times.
  • Lamp Turret–6

  • more..

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
  • Lamp Turret–4

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The     S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame; 5cm single slot all titanium burner for     oxygen rich flame.

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The     S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The     S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–4.
  • Lamp Current Adjustment–Automatic adjustment and display.Wide pulse current: 0~25mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.

  • more..

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.The S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret– 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity)

  • more..

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The    S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Number– 2 lamps (one preheating).
  • Burner– 10cm single slot all titanium burner.

  • more..

    Atomic Emission Spectrophotometer–LAES-10

  • Charge Capacitance– Pre-burn 7 µf, Expose 1.5 µf
  • Discharge Inductance– Pre-burn 35 µh; Expose 70µh
  • Spectrum Range– 175-450 nm
  • Optical Channels– up to 36 channels
  • Width of entrance slit– 20 µm
  • Width of exit slit– 50 µm, 75 µm

  • more..

    Atomic Fluorescence Spectrophotometer Environmental Protection Type– LAFS 100

  • With "High efficiency Hg-elimination Technique.
  • Determination of Hg, As, Sb, Bi, Se, Te, Pb, Sn, Ge, Zn and Cd.
  • Quartz atomizer with "full-ceramics infrared heating temperature control" technique has super long lifetime.
  • Realize two or three elements determination simultaneously.

  • more..

    UV-Visible Spectrophotometers LUV Series

  • Optical System– Double Beam
  • Wavelength Range– 190 ~1100 nm
  • Spectral Bandwidth– 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector– Silicon photo diode
  • Photometric Accuracy– ±0.3%T (0~100%T); ±0.002A (0~1A)

  • more..

  • Optical System– Double Beam
  • Wavelength Range– 190~900nm
  • Spectral Bandwidth– 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
  • Detector– Photomultiplier
  • Photometric Accuracy– ± 0.3%T (0~100%T), ± 0.002A (0~0.5A), ± 0.004A (0.5A~1A)

  • more..

  • Optical System– Single Beam
  • Wavelength Range– 190 - 1100nm
  • Spectral Bandwidth– 2nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector– Silicon photodiode
  • Photometric Accuracy– 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)

  • more..

  • Optical System– Single Beam
  • Wavelength Range– 190 - 1100nm
  • Spectral Bandwidth– 2nm (5nm, 1nm optional)
  • Detector– Silicon photo-diode
  • Photometric Accuracy– 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)

  • more..

  • Wavelength Range– 190 - 1100 nm
  • Spectral Bandwidth– 5nm (1, 2, 4nm optional)
  • Detector– Silicon Photodiode
  • Photometric Accuracy– 0.5% T

  • more..

    Visible Spectrophotometer L-VIS–400

  • Optical System– Single Beam
  • Wavelength Range– 320 - 1100nm
  • Spectral Bandwidth– 2.0nm (5nm, 1nm optional)
  • Detector– Silicon photodiode
  • Photometric Accuracy– ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)

  • more..

    UV-VIS Split Beam Spectrophotometers - LUV 1000 Series

  • Optical System– Split Beam
  • Wavelength Range– 190–1100nm
  • Spectral Bandwidth– 2nm fixed slit
  • Detector– Silicon photodiode
  • Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
  • more..


  • Optical System– Split Beam
  • Wavelength Range– 190–1100nm
  • Spectral Bandwidth– 0.5, 1, 2, 5nm (variable slit)
  • Detector– Silicon photodiode
  • Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
  • more..


    UV- VIS Double Beam Spectrophotometers- LUV 1000 Series

  • Optical System– Double Beam
  • Wavelength Range– 190 – 1100nm
  • Spectral Bandwidth– 2nm (fixed slit)
  • Detector– Silicon photodiode
  • Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
  • more..


  • Optical System– Double Beam
  • Wavelength Range– 190 – 1100nm
  • Spectral Bandwidth– 0.5, 1, 2, 5nm (Variable slit)
  • Detector– Silicon photodiode
  • Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
  • more..


    UV- VIS Double Beam Spectrophotometer- LUV 1000E

  • Optical System– Double Beam
  • Wavelength Range– 190 – 900nm
  • Spectral Bandwidth– 0.5, 1, 2, 5nm (Variable slit)
  • Detector– Silicon photodiode
  • Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
  • more..


       
    Optional Accessories for UV-VIS Spectrophotometers 1000 Series
    Specular reflection unit
    Automatic 8-cell holder
    Changeable Angles Solid Samples Cell Holder
    Solid sample cell holder
    Dual-Channels sipper pump
    Constant-temperature cell holder
    50mm Long-pathlength cell holder
    Short-pathlength cell holder
    Peltier thermoelectric cell holder
    Test Tube Holder